2015年6月13日星期六

Argon (NH3)infrared gas analyzer/argon gas analyzer

Chinacoal07 Argon (NH3)infrared gas analyzerargon gas analyzer,NH3 gas analyzer

Argon (NH3)infrared gas analyzer/argon gas analyzer


Product Introduction

JNYQ-1-41 series infrared gas analyzer

This series gas analyzer is a new industrial grade gas analyzer developed by our company, it adopt imported  high-precision infrared sensor and use advanced computer processing technology

Technical specification:

Measuring gases: CO,CO2,SO2,CH4,NH3 etc.optional.

Linear measurement features

Sensitivity:<0.2% F.S

Linear error:<2% F.S

Zero wander: <1 % F.S/7d

Measuring range wander:<1 % F.S/7d

Repeatability:<0.5 % F.S

Response time: <10s

Analog output:0/4-20mA,max Load 200Ω

IP Grade:IP 66

Power:220VAC±10%,50HZ±1%

Temperature:0-45℃

Relative humidity:90% RH

Feature:

l Adopt imported dual wavelength infrared gas detection technology,High precision measurement,stable

l Long life time,  automatic calibration

l High function-price ratio,specially for industry.

l Alarm point can be set as your request 

l Standard RS485 and RS232 communication interface

Measuring gas available:
Gas
ppm
Gas
ppm
Gas
ppm
Gas
ppm
CO
30
C2H2
500
CH
500
NO
300
CO2
20
C2H4
1000
SO2
300
SF6
300
CH4
100
C2H6
500
NH3
500



Other model available:
Model
gas
measuring range
error
Dimension
Theory
remark
JNYQ—I-41M
CO
0.00~100PPm
≤±1%F.S
454×180
infrared 
on line type
JNYQ—I-41C
CO
0.00~100%
≤±1%F.S
454×180
infrared

JNYQ—I-41M
CO2
0.00~100PPm
≤±1%F.S
454×180
infrared

JNYQ—I-41C
CO2
0.00~100%
≤±1%F.S
454×180
infrared

JNYQ—I-41M
CH4
0.00~500PPm
≤±1%F.S
454×180
infrared

JNYQ—I-41C
CH4
0.00~100%
≤±1%F.S
454×180
infrared

JNYQ—I-41M
SO2
0.00~300PPm
≤±1%F.S
454×180
infrared

JNYQ—I-41C
SO2
0.00~100%
≤±1%F.S
454×180
infrared

JNYQ—I-41M
NH3
0.00~500PPm
≤±1%F.S
454×180
infrared

JNYQ—I-41C
NH3
0.00~100%
≤±1%F.S
454×180
infrared

JNYQ—I-41M
NO
0.00~300PPm
≤±1%F.S
454×180
infrared

JNYQ—I-41C
NO
0.00~100%
≤±1%F.S
454×180
infrared

JNYQ—I-41M
SF6
0.00~300PPm
≤±1%F.S
454×180
infrared

JNYQ—I-41C
SF6
0.00~100%
≤±1%F.S
454×180
infrared

JNYQ—I-41M
C2H2
0.00~500PPm
≤±1%F.S
454×180
infrared

JNYQ—I-41C
C2H2
0.00~100%
≤±1%F.S
454×180
infrared

JNYQ—I-41M
C2H4
0.00~1000PPm
≤±1%F.S
454×180
infrared

JNYQ—I-41C
C2H4
0.00~100%
≤±1%F.S
454×180
infrared

JNYQ—I-41M
C2H6
0.00~500PPm
≤±1%F.S
454×180
infrared

JNYQ—I-41C
C2H6
0.00~100%
≤±1%F.S
454×180
infrared

JNYQ—I-4C
methane
0.00~100%
≤±1%F.S
454×180
infrared

JNYQ—I-44EX
CO etc
0.00~100%
≤±1%F.S
450×650
infrared
on-line type g,explosion-proof

没有评论:

发表评论